Series representative image — not a model-specific photograph.
SICK / MODEL
RLY3-LOOP100
RLY3 ReLy Safety RelaysSICK RLY3-LOOP100 — Application: Evaluation unit; SICK Part Number: 1100696; Safety Contact Configuration: 3 instantaneous N/O.
- Application
- Evaluation unit
- SICK Part Number
- 1100696
- Safety Contact Configuration
- 3 instantaneous N/O
- Power Supply Type
- PELV or SELV
Overview
Use the exact ordering code and the applicable operating instructions. Catalogue ratings describe the module, not the validated safety level of a complete machine. Current availability has not been checked.
Specifications
| Application | Evaluation unit |
|---|---|
| SICK Part Number | 1100696 |
| Safety Contact Configuration | 3 instantaneous N/OImmediate and release-delayed safety paths are distinguished; non-safe feedback, signaling and diagnostic outputs are not included here. |
| Power Supply Type | PELV or SELV |
| Compatible Sensor Types | Flexi Loop safe series connection |
| Instantaneous Safety Paths (N/O) | 3 |
| Nominal Housing Width | 18 mmNominal housing width. Front-connector envelope and installation dimensions are shown separately in the p.14 drawings. |
| Connection Type | front connector with spring terminals |
| Catalogue Safety Integrity Level | SIL3 (IEC 61508) SILCL3 (IEC 62061)Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine. |
| Catalogue Safety Category | Category 4 (ISO 13849-1)Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine. |
| Catalogue Performance Level | PL e (ISO 13849-1)Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine. |
| Mission Time | 20 years (ISO 13849-1)Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine. |
| PFHd (Mean Dangerous Failure Probability per Hour) | 1.5 x 10^-9 /hCatalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine. |
| Stop Category (IEC 60204-1) | 0Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine. |
| Listed Monitoring Functions | Flexi Loop monitoring; Restart interlock; External device monitoring (EDM) |
| Reset | automatic manual |
| Safety Inputs | 2 |
| Reset Pushbutton / EDM Inputs | 1 |
| Display Elements | LEDs |
| Supply Voltage Vs | 24 V DC (16.8 V to 30 V) |
| Residual Ripple | ≤ 2.4 V |
| Power Consumption | ≤ 2.5 W (DC) |
| Safety Input Voltage HIGH | 24 V DC (11 V to 30 V) |
| Safety Input Voltage LOW | 0 V DC (-3 V to 5 V) |
| Safety Input Current | 4 mA to 6 mA |
| Activation Time Tolerance Between Start Buttons | ≤ 3 s |
| Configuration Method | Hard wired; DIP switches |
| Reset / EDM Voltage HIGH | 24 V DC (11 V to 30 V) |
| Reset / EDM Voltage LOW | 0 V DC (-3 V to 5 V) |
| Reset / EDM Input Current | 4 mA to 6 mA |
| Instantaneous Safety Path Response Time | 79 ms |
| Instantaneous Safety Contact Type | N/O contacts, positively guided |
| Safety Contact Material | Silver alloy, gold flashed |
| Instantaneous Safety Path Switching Voltage | 10 V AC to 230 V AC 10 V DC to 230 V DC |
| Instantaneous Safety Path Switching Current | 10 mA to 6 A |
| Maximum Total Safety Path Current | 12 AMaximum total current across the enabling paths; observe the operating instructions. |
| Mechanical Life (Switching Cycles) | 10^7 cycles |
| Overvoltage Category | III (EN 60664-1) |
| Rated Impulse Withstand Voltage | 6 kV (EN 60664-1) |
| Application Diagnostic Outputs (Not Safe): Count | 2 |
| Application Diagnostic Outputs (Not Safe): Type | Push-pull semiconductor output, short-circuit protected |
| Application Diagnostic Outputs (Not Safe): Voltage HIGH | ≥ Vs - 3 V |
| Application Diagnostic Outputs (Not Safe): Voltage LOW | ≤ 3 V |
| Application Diagnostic Outputs (Not Safe): Input Current (NPN) | ≤ 15 mA |
| Application Diagnostic Outputs (Not Safe): Output Current (PNP) | ≤ 120 mA |
| Test Pulse Outputs (Not Safe): Count | 1 |
| Test Pulse Outputs (Not Safe): Type | PNP semiconductors, short-circuit protected |
| Test Pulse Outputs (Not Safe): Output Voltage | ≥ Vs - 3 V |
| Test Pulse Outputs (Not Safe): Pulse Width | 2 ms |
| Test Pulse Outputs (Not Safe): Pulse Interval | 40 ms |
| Weight | 160 g |
| Enclosure Rating | IP20 (IEC 60529) |
| Ambient Operating Temperature | -25 to +55 °C |
| Storage Temperature | -25 to +70 °C |
| Air Humidity | 10 to 95%, non-condensing |
| Interference Emission | According to IEC 61000-6-4Standard identifiers and values are quoted from the 2021 catalogue; no current certificate or complete-system compliance is inferred. |
| Interference Resistance | According to IEC 61326-3-1; IEC 61000-6-2; IEC 60947-5-1Standard identifiers and values are quoted from the 2021 catalogue; no current certificate or complete-system compliance is inferred. |
| Maximum Series-connected Sensors | Up to 32 sensors with Flexi LoopApplies to the Flexi Loop system arrangement described on p.5; confirm system configuration and operating instructions. |