Series representative image — not a model-specific photograph.
SICK / MODEL
RLY3-OSSD400
RLY3 ReLy Safety RelaysSICK RLY3-OSSD400 — Application: OSSD output expansion module; SICK Part Number: 1099971; Safety Contact Configuration: 4 instantaneous N/O.
- Application
- OSSD output expansion module
- SICK Part Number
- 1099971
- Safety Contact Configuration
- 4 instantaneous N/O
- Power Supply Type
- Passive (no active voltage supply)
Overview
Use the exact ordering code and the applicable operating instructions. Catalogue ratings describe the module, not the validated safety level of a complete machine. Current availability has not been checked.
Specifications
| Application | OSSD output expansion module |
|---|---|
| SICK Part Number | 1099971 |
| Safety Contact Configuration | 4 instantaneous N/OImmediate and release-delayed safety paths are distinguished; non-safe feedback, signaling and diagnostic outputs are not included here. |
| Power Supply Type | Passive (no active voltage supply) |
| Compatible Sensor Types | Safety sensors with OSSDs |
| Instantaneous Safety Paths (N/O) | 4 |
| Nominal Housing Width | 28 mmNominal housing width. Front-connector envelope and installation dimensions are shown separately in the p.14 drawings. |
| Connection Type | front connector with spring terminals |
| Catalogue Safety Integrity Level | SIL3 (IEC 61508) SILCL3 (IEC 62061)Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine. |
| Catalogue Safety Category | Category 4 (ISO 13849-1)Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine. |
| Catalogue Performance Level | PL e (ISO 13849-1)Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine. |
| Mission Time | 20 years (ISO 13849-1)Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine. |
| PFHd (Mean Dangerous Failure Probability per Hour) | 1.0 x 10^-9 /hCatalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine. |
| Stop Category (IEC 60204-1) | 0Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine. |
| Listed Monitoring Functions | Path for external device monitoring (EDM) |
| Safety Inputs | 2 |
| Feedback Paths (Not Safe) | 1 |
| Signaling Paths (Not Safe) | 1 |
| Display Elements | LEDs |
| Input Circuit Power Consumption | ≤ 2.5 W (DC) |
| Safety Input Voltage HIGH | 24 V DC (15 V to 30 V) |
| Safety Input Voltage LOW | 0 V DC (-3 V to 5 V) |
| Safety Input Current | ≤ 60 mA |
| Safety Input Test Pulse Width | ≤ 1 ms |
| Safety Input Test Pulse Rate | ≤ 10 Hz |
| Instantaneous Safety Path Response Time | 12 ms |
| Instantaneous Safety Contact Type | N/O contacts, positively guided |
| Safety Contact Material | Silver alloy, gold flashed |
| Instantaneous Safety Path Switching Voltage | 10 V AC to 230 V AC 10 V DC to 230 V DC |
| Instantaneous Safety Path Switching Current | 10 mA to 6 A |
| Maximum Total Safety Path Current | 12 AMaximum total current across the enabling paths; observe the operating instructions. |
| Mechanical Life (Switching Cycles) | 10^7 cycles |
| Overvoltage Category | III (EN 60664-1) |
| Rated Impulse Withstand Voltage | 6 kV (EN 60664-1) |
| Feedback Path (Not Safe) Contact Type | N/C contact, positively guided |
| Feedback Path (Not Safe) Contact Material | Silver alloy, gold flashed |
| Feedback Path (Not Safe) Switching Voltage | 10 V AC to 30 V AC 10 V DC to 30 V DC |
| Feedback Path (Not Safe) Switching Current | 3 mA to 100 mA |
| Feedback Path (Not Safe) Mechanical Life | 10^7 cycles |
| Signaling Path (Not Safe) Contact Type | N/C contact, positively guided |
| Signaling Path (Not Safe) Contact Material | Silver alloy, gold flashed |
| Signaling Path (Not Safe) Switching Voltage | 10 V AC to 30 V AC 10 V DC to 30 V DC |
| Signaling Path (Not Safe) Switching Current | 10 mA to 100 mA |
| Signaling Path (Not Safe) Mechanical Life | 10^7 cycles |
| Weight | 180 g |
| Enclosure Rating | IP20 (IEC 60529) |
| Ambient Operating Temperature | -25 to +55 °C |
| Storage Temperature | -25 to +70 °C |
| Air Humidity | 10 to 95%, non-condensing |
| Interference Emission | According to IEC 61000-6-4Standard identifiers and values are quoted from the 2021 catalogue; no current certificate or complete-system compliance is inferred. |
| Interference Resistance | According to IEC 61326-3-1; IEC 61000-6-2; IEC 60947-5-1Standard identifiers and values are quoted from the 2021 catalogue; no current certificate or complete-system compliance is inferred. |
Document
PDFsick-rly3-safety-relays-en.pdfSICK ReLy RLY3 Safety Relays - English Product Information (8021876/2021-10-22) · Shared series documentRequest this model
Send the exact ordering code, quantity or product list.