SICK / MODEL

GTE6-P4211

G6 Miniature Photoelectric Sensors

SICK GTE6-P4211 — Detection Mode: Diffuse-reflective (energetic); Sensing Distance: 300 mm; Output Type: PNP.

Detection Mode
Diffuse-reflective (energetic)
Sensing Distance
300 mm
Output Type
PNP
Housing
Rectangular miniature housing

Overview

90% remission white target according to DIN 5033. Chart: white operating 15–250 mm, typical 10–300 mm; grey 18% operating 35–120 mm, typical 30–140 mm. 100 mA maximum; this page does not state the voltage/temperature derating used on other G6 pages. Series representative image only. User approval pending.

Specifications

Detection ModeDiffuse-reflective (energetic)
Sensing Distance300 mmTypical maximum, not guaranteed operating distance. 90% remission white target according to DIN 5033. Chart: white operating 15–250 mm, typical 10–300 mm; grey 18% operating 35–120 mm, typical 30–140 mm.
Output TypePNPNPN open collector or PNP Q; applicability read from shaded model columns.
HousingRectangular miniature housingDimensions and product drawing on p.6
SICK Part Number1050710Exact part number in ordering table.
Connection TypeM8 connector, 4-pinModel applicability read from the connection matrix.
Cable LengthNot applicable (integral M8 connector)No integral cable length listed for the connector variant.
Supply Voltage10–30 V DCLimit values; operation in short-circuit protected network, maximum 8 A.
IP RatingIP67Catalogued enclosure rating.
Response Time< 1250 µsSignal transit time with resistive load.
Operating Temperature−25 to +55 °C
Storage Temperature−40 to +70 °C
Housing MaterialABS, PC, PMMAABS, PC and PMMA as listed; do not infer which material forms each component.
Light SourceRed LED, 650 nmAverage service life 100000 h at ambient +25 °C.
Current Consumption≤ 30 mAWithout load.
Response FrequencyTyp. 500 HzLight/dark ratio 1:1.
Operation ModeLight/dark switching via rotary selector
Operating Distance / Range250 mm90% remission white target according to DIN 5033. Chart: white operating 15–250 mm, typical 10–300 mm; grey 18% operating 35–120 mm, typical 30–140 mm.
G6 VariantStandard
Optical AdjustmentPotentiometer (operating distance)
Light Spot Diameter7 mm at 90 mmAt the stated reference distance.
Maximum Output Current / Derating100 mA maximum; this page does not state the voltage/temperature derating used on other G6 pages.Keep model-family-specific AND/OR condition.
Approximate Weight20 gApproximate, dependent on cable/connector.
Included Accessories (Catalogued)Not stated for this model in the delivery matrixApplicability from shaded delivery row; an unshaded cell is not used to assert that no accessories are supplied.

Document

PDFsick-g6-global-sensor-en.pdfSICK G6 Global Sensor Catalog - English (8014182, 2012-10-12) · Shared series document

Request this model

Send the exact ordering code, quantity or product list.

Request a Quote
WhatsApp

Request a Quote

Fields marked * are required.

PDF, XLS, XLSX, CSV, DOC, DOCX, JPG or PNG
Up to 5 files · 10 MB each · 50 MB totalDo not include sensitive personal information or documents you are not permitted to share.

A confirmation page appears only after your inquiry is recorded. For email correspondence, contact sales@brolenz.com.